l865 lxs ex medium intensity white

According to ICAO – Annex 14 Medium Intensity Obstruction Lights – Type A Ex, B Ex or C Ex – have tobe used where the obstacle is particularly large and the height of the surrounding ground is morethan 45m in hazardous areas.Medium Intensity Obstacle Lights Type A Ex and C Ex have to be used […]

Complex systems series

According to the client request, as per dedicate technical sheet and / ora single line diagram, our Technical Office selects the dimension of theenclosures suitable for specific use, determining the inside layout, withthe purpose to respect all the parameters both dimensional according tothe parameters as per ATEX and/or IEC ex certificate.

EF series operators 

The EF series control devices are normally installed as external operators forenclosures EJB, EJC and GUB used in the industrial plants, with potentialhazardous atmospheres of gases and combustible dusts, and thereforeclassified as Zone 1 – 2 – 21 – 22.

EJB series enclosures

The EF series control devices are normally installed as external operators forenclosures EJB, EJC and GUB used in the industrial plants, with potentialhazardous atmospheres of gases and combustible dusts, and thereforeclassified as Zone 1 – 2 – 21 – 22.

EJBX series enclosures

The EF series control devices are normally installed as external operators forenclosures EJB, EJC and GUB used in the industrial plants, with potentialhazardous atmospheres of gases and combustible dusts, and thereforeclassified as Zone 1 – 2 – 21 – 22.

EJC™ series enclosures series

The EF series control devices are normally installed as external operators forenclosures EJB, EJC and GUB used in the industrial plants, with potentialhazardous atmospheres of gases and combustible dusts, and thereforeclassified as Zone 1 – 2 – 21 – 22.

ESXseries enclosures series

The EF series control devices are normally installed as external operators forenclosures EJB, EJC and GUB used in the industrial plants, with potentialhazardous atmospheres of gases and combustible dusts, and thereforeclassified as Zone 1 – 2 – 21 – 22.

GUB and GUBW series enclosures

The enclosures GUB and GUBW are normally installed in the industrialplants, with potential hazardous atmospheres of gases and combustibledusts, and therefore classified as Zone 1 – 2 – 21 – 22.These enclosures are primarily used with the function of:• Cable termination unions, with terminals for derivation or change sectioncables.• Protection of electric circuits, with automatic […]

Valves V series

Drain and breather valves V is particularly recommended for tropicalatmospheres with high humidity and wide temperature changes, where theassociated water condensation can be a problem. The valve is mounted atthe bottom of housings or on seals in conduit runs so that condensationwater can be drained off and damage to wiring or to electrical componentscan be […]